We (@redford, @mrtick and I) have reverse engineered the PLC code of NEWAG Impuls EMUs. These trains were locking up for arbitrary reasons after being serviced at third-party workshops. The manufacturer argued that this was because of malpractice by these workshops, and that they should be serviced by them instead of third parties.

  • 50gp@kbin.social
    link
    fedilink
    arrow-up
    17
    ·
    1 year ago

    the idiots who engineered the killswitch and didnt whistleblow should get some too

    • deegeese@sopuli.xyz
      link
      fedilink
      English
      arrow-up
      12
      ·
      1 year ago

      Yes, the people who committed sabotage should be arrested and forced to testify against their superiors who planned and ordered sabotage.