We built a house 7 years ago and it’s insulated and has double glazing. I’ve installed Home Assistant with temp sensors in the bed rooms and seeing 70%+ humidity levels. Temperature is always above 16c

We ventilate it, but still it’s 70% in the bedrooms. WHO recommends 40-60%, so we’re a bit worried.

Living room is around 55% during the day when we have the heat pump set at 21c.

As it’s pretty humid outside I think it’s almost impossible to get it lower, but are there any other tips? I don’t want to run dehumidifiers. Would an HRV like system help?

  • sylverstream@lemmy.nzOP
    link
    fedilink
    arrow-up
    5
    ·
    1 year ago

    What do you mean exactly you ventilating. Mechanical ventilation?

    We’ve got mechanical ventilation in the bathrooms.

    But I meant just old school opening all the windows :)

    TLDR: your house is humid because it’s well sealed and the builders couldn’t be bothered putting in mechanical ventilation because we are 20 years behind the rest of the world.

    Yes, I understand that, we generate moist from cooking/breathing/washing and that has to go somewhere. We’ve got many windows open a little bit 24/7.

    I’m from Europe, and yes, houses are better insulated, we had double glazing 30 years ago, and now have triple glazing, but ventilation was never an issue. We just open our windows to ventilate for e.g. an hour and that’s it.

    • innercitadel@lemmy.nz
      link
      fedilink
      arrow-up
      2
      ·
      1 year ago

      Thanks for further details. I would definitely invest in getting HVAC installed in that instance or if cost is an issue then at minimum install simple positive pressure mechanical ventilation from the outside into the bedrooms. This should fix your problem. It sounds like windows aren’t enough because the house is well sealed, so you need a mechanical solution. Please don’t get DVS from the attic.

      I live in a new house with HVAC and leave the mechanical ventilation on when not heating or cooling and it keeps moisture levels low. I also got HVAC retrofitted into my previous house which made a massive difference in moisture. I’ll never live in a house without HVAC in the future if I can help it.

      • sylverstream@lemmy.nzOP
        link
        fedilink
        arrow-up
        3
        ·
        1 year ago

        We do have HVAC, in a heat pump. It’s running all day. A complete system like HRV is a bit too much for now. The dry setting is annoying as it is cooling. Not handy mid winter.

        • innercitadel@lemmy.nz
          link
          fedilink
          arrow-up
          2
          ·
          1 year ago

          You mean a split system? A heat pump usually refers to a split system which doesn’t have the V in HVAC as it just recirculates air. HRV is the ventilation from the attic thing, please don’t get that.

          HVAC generally refers to ducted aircon with mechanical ventilation. The “heat pump” sits in the attic. Fresh air is taken in from the outside through the soffit. Ducts run from the “heat pump” into each room.

          If a ducted system is too expensive then you should install plain mechanical positive pressure ventilation from the outside (not HRV/DVS) Depending on your house it is possible to DIY this using stuff from Bunnings. You could even link the fan to your Home Assistant and get it to activate when the humidity reaches a certain threshold. This should fix your problem. If it causes the house to get cold by doing this then you could install a mechanical heat recovery device.

          • sylverstream@lemmy.nzOP
            link
            fedilink
            arrow-up
            3
            ·
            1 year ago

            Thanks mate, that is very useful. Yes, we indeed only have a heat pump.

            I looked into HRV/DVS alternatives some time ago, and Cleanaire was recommended on e.g. Geekzone; which gets the air from outside & heats it. Quote was $4-5k which is a bit steep as we’re not sure how long we’ll be living here.

            A DIY option for a PIV isn’t too bad. I could leave it running overnight and use the heat pump to keep the house above 16c.

            I also bought a small dehumidifier as a stop gap.

            I’ve left the heat pump running on dry / heat cycles overnight (1 hour dry to 17c, 1 hour heat to 19c). Didn’t do anything, RH at the end was exactly the same as the night before.

            • innercitadel@lemmy.nz
              link
              fedilink
              arrow-up
              3
              ·
              1 year ago

              Oh wow mechanical heat recovery systems have jumped in price. They were 2-3k a few years ago. The way mechanical heat recovery works is kind of like penguin legs. The inflow and exhaust airflows pass by each other. So the warm exhaust air passively heats the cooler inflow air. So they are quite basic things that are very cheap to run. I guess another kiwi tax. Done some googling for pricing and it does appear 5-6k is the going rate now. E.g. another option: https://www.smooth-air.co.nz/home/hex390

              What about something like this: https://www.smartvent.co.nz/why-smartvent/ that should also improve the humidity. Doesn’t say price though. They seem to have a variety of options including positive pressure which should be much cheaper than a heat recovery system. https://www.smartvent.co.nz/smartvent-positive-advance/

              Here’s some more information about heat recovery systems and why DVS/HRV from the attic are shit. https://www.smarterhomes.org.nz/smart-guides/heating-cooling-and-insulation/ventilation-and-heat-recovery-systems/

              • sylverstream@lemmy.nzOP
                link
                fedilink
                arrow-up
                2
                ·
                1 year ago

                Thanks for the details!

                Smooth air has kits for just ventilation for 1.5k for 2 rooms. Smartvent is more expensive, like 4k, they have some pricing.

                I don’t need a lot of bells and whistles. I can automate it myself. Just an outdoor outlet and an indoor outlet, ventilator and two pipes for just the living room.

                I read your article, they say HRV/DVS is bad for heating, but not if you use it just for ventilation?

                One other easier option is to just have a simple diy DVS by using the air from the attic. I’m going to check the moisture levels there first.

                • innercitadel@lemmy.nz
                  link
                  fedilink
                  arrow-up
                  2
                  ·
                  edit-2
                  1 year ago

                  That should work if you bring it to the soffit instead of a different room. However youre paying extra for the temperature sensor. Don’t get the air from the attic, it’s not healthy air, I don’t care how good the filters are, it is something unheard of elsewhere in the developed world. I would rather have nothing than air come in from the attic. Please rid yourself of the idea of venting from the attic.

                  I have these links saved in my bookmarks when I first researched this 10 years ago and retrofitted a ducted HVAC system in my previous house.

                  https://www.energyvanguard.com/blog/Case-Closed-Get-Those-Air-Conditioning-Ducts-out-of-the-Attic

                  https://www.nrel.gov/docs/fy10osti/48163.pdf

                  In many countries in Europe houses actually have to have their ventilation/insulation performance tested and pass the test (e.g. blower door for air tightness). We have gotten better at insulating but our builders still don’t generally understand the importance of mechanical ventilation. Cue Mouldy homes chapter 2.

                  Balanced heat recovery mechanical ventilation > positive pressure ventilation > negative pressure ventilation > nothing > air from the attic.

                  Just my opinion. I don’t work in the industry. Just a geek.

                  • sylverstream@lemmy.nzOP
                    link
                    fedilink
                    arrow-up
                    2
                    ·
                    1 year ago

                    Thanks. I had a look at those articles. I’m not an expert, but they seem to talk about the temperature / lack of insulation in the attic, not about the air quality. They recommend putting the pipes inside the thermal enclosure.

                    I think you’re still right though, better to get air from the outside.

                    I did some reading, and I found this article where they talk about lack of attic ventilation being a bad thing. Overseas it seems to be a standard now. Think next step is to measure the attic as well to see if I need to ventilate that as well.

                    Another read about attic ventilation here

    • cabbage@lemmy.nz
      link
      fedilink
      arrow-up
      2
      ·
      edit-2
      1 year ago

      4 year old house, double glazing. We have the heat pump set at 21dg on 24x7 all winter and never really open windows.

      Current temps and moisture levels:

      If you’re worried about moisture I recommend a dehumidifier, those things work wonders and much cheaper than retrofitting ventilation like the other poster mentioned.

      I guess it’s worth mentioning, we have a tumble drier in the garage so the house doesn’t get any moisture from drying clothes.

      • sylverstream@lemmy.nzOP
        link
        fedilink
        arrow-up
        2
        ·
        1 year ago

        Thanks. Those numbers are similar to ours. We never really opened windows either, we’re aiming to do that daily from now on.

        Just bought a dehumidifier. Indeed easiest and cheapest solution.

          • sylverstream@lemmy.nzOP
            link
            fedilink
            arrow-up
            3
            ·
            1 year ago

            We only a little bit in certain clothes and in the bottom of our alu window frames.

            Still above 60% is apparently not healthy. I’d recommend to look into it.

      • TagMeInSkipIGotThis@lemmy.nz
        link
        fedilink
        arrow-up
        2
        ·
        1 year ago

        A lot of modern heat-pumps have a dehumidifier mode. But likely if they’re set to Auto they’ll never switch to using it I think.